RecommendedMD520-2T15BS-INT
Why this drive The original drive is rated at 46.8 A in heavy duty. This model supplies 60 A in heavy duty (15 kW nominal).
- Current
- 46.8 A · published
- Duty
- Heavy duty · default
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation

MD520-2T18.5BS-INT
Capacity The original drive is rated at 46.8 A in heavy duty. This model supplies 75 A in heavy duty (18.5 kW nominal).
- Current
- 46.8 A · published
- Duty
- Heavy duty · default
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation

MD520-2T22BS-INT
Capacity The original drive is rated at 46.8 A in heavy duty. This model supplies 91 A in heavy duty (22 kW nominal).
- Current
- 46.8 A · published
- Duty
- Heavy duty · default
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation
Edit Requirements
Installation Checks and Manuals
What to Confirm
- The comparison uses 230 V AC. Confirm the supply at your site.
- Confirm whether the existing installation uses a drive safety function.
- Confirm the required enclosure rating and cabinet protection.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the peak current, duration and overload repeat interval.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.
Documents
MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFWhat to Confirm
- The comparison uses 230 V AC. Confirm the supply at your site.
- Confirm whether the existing installation uses a drive safety function.
- Confirm the required enclosure rating and cabinet protection.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the peak current, duration and overload repeat interval.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.
Documents
MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFWhat to Confirm
- The comparison uses 230 V AC. Confirm the supply at your site.
- Confirm whether the existing installation uses a drive safety function.
- Confirm the required enclosure rating and cabinet protection.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the peak current, duration and overload repeat interval.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.