Skip to catalogue results

Compare Inovance Options for FX5UC-96MT/DSS

Official distributor for Australia and New Zealand
Inovance H5U family illustration
Manufacturer illustration. Confirm the exact physical variant.

H5U-1614MTD-INT

Why this option

  • Covers the documented controller supply
  • 64 digital inputs for 48 published points
  • 128 sourcing outputs for 48 published points

Equipment to include 1 × GL20-RTU-ECT32-INT · 3 × GL20-1600END-INT · 1 more in the retrofit plan

Review Full Comparison
Edit Requirements

Confirm the supply, I/O wiring, network roles and programme migration.

Must stay
Retrofit Equipment, Checks and Manuals

What This Retrofit Needs

Equipment to Include

  • 1 × GL20-RTU-ECT32-INT · EtherCAT coupler; ESI/PDO integration requires validation
  • 3 × GL20-1600END-INT · Ordinary24V digital input module
  • 8 × GL20-0016ETP-INT · PNP ordinary24V digital output module
  • Recreate the PLC programme and map the installed I/O.

Checks Before Quoting

  • Confirm input wiring, output loads, programme timing, installed expansion and active network roles.

Documents

H5U brochure V0.0PDFInovance H5U A13 hardware — 32-axis base model, memory, output groups and mechanical drawingPDFInovance H5U-1614MTD-INT — exact international PLC memory, shared axis budget and I/O tablePDF

Full Specification Comparison

SpecificationFX5UC-96MT/DSS
DC supply
FX5UC-96MT/DSS24 V DCH5U-1614MTD-INT
24 V DC
Dimensions (W × H × D)
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
83 × 90 × 95 mm
Digital inputs
FX5UC-96MT/DSS48H5U-1614MTD-INT
16
Digital input type
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
NPN/PNP
Digital outputs
FX5UC-96MT/DSS48H5U-1614MTD-INT
14
Digital output type
FX5UC-96MT/DSSPNP sourcing transistorH5U-1614MTD-INT
NPN sink transistor
High-speed inputs
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
4
High-speed outputs
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
8
Output group current limit
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
High-speed 0.8 A per 4 outputs · standard 0.8 A per 4 or 1.6 A per 6
Motion control
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
32 axes
Expansion system
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
16 local modules
Variable storage
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
2 MB
Retained variable storage
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
256 kB
Ethernet ports
FX5UC-96MT/DSS1H5U-1614MTD-INT
1
Control networks and roles
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
EtherCAT master · Modbus TCP · TCP sockets
Serial interface
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
One RS485 interface; Modbus RTU and free protocol
Engineering software
FX5UC-96MT/DSSGX Works3H5U-1614MTD-INT
Not listed
Program memory
FX5UC-96MT/DSSNot listedH5U-1614MTD-INT
200 ksteps

▲ and ▼ show numerical differences. Check supply, configuration and installation before choosing.

Brand names and part numbers are used only to identify the products being compared. Universal Systems is not affiliated with or endorsed by these manufacturers. Comparisons use published specifications and are a starting point, not a confirmed replacement. Our engineers confirm suitability before any order.