Skip to catalogue results

Compare Inovance Options for 3G3M1-A2007

Official distributor for Australia and New Zealand
Inovance MD520 family illustration
Illustration

MD520-2T1.5BS-INT

Why this drive The original drive is rated at 5 A in hHD · heavy load. This model supplies 7.2 A in heavy duty (1.5 kW nominal).

Published capacity covers 7.5 A for 60 s and 10 A for 0.5 s. Confirm repeat interval.

Current
5 A · published
Duty
HHD · heavy load · default
Supply
230 V AC · 3-phase
Network
Confirm at quotation
Temperature
40 °C · rating basis
Review Full Comparison
Edit Requirements
Temperature, Altitude and Overload

Enter peak current and duration together to use the machine’s own overload requirement.

Installation Checks and Manuals

What to Confirm

  • Verify the motor type, encoder and control functions, braking circuit, cooling and switching frequency before ordering.
  • Check the existing EMC class, cable length and earthing arrangement.
  • Confirm the selected Omron duty and its ambient-temperature and carrier-frequency limits.
  • The comparison uses 230 V AC. Confirm the supply at your site.
  • Verify the existing STO circuit, connections and required safety functions.
  • Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
  • Confirm the overload repeat interval against the drive’s documented limits.
  • Confirm site temperature and altitude.
  • Confirm the switching frequency used for the published rating.
  • Confirm motor nameplate and braking requirements before ordering.

Documents

MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDF

Full Specification Comparison

Specification3G3M1-A2007
Supply voltage
3G3M1-A2007200–240 V ACMD520-2T1.5BS-INT
200–240 V AC
Input phases
3G3M1-A20073MD520-2T1.5BS-INT
3
Motor power, heavy duty
3G3M1-A2007Not listedMD520-2T1.5BS-INT
1.5 kW
Output current, heavy duty
3G3M1-A2007Not listedMD520-2T1.5BS-INT
7.2 A
Overload, heavy duty
3G3M1-A2007Not listedMD520-2T1.5BS-INT
150% for 60 s
Motor power, normal duty
3G3M1-A2007Not listedMD520-2T1.5BS-INT
2.2 kW
Output current, normal duty
3G3M1-A2007Not listedMD520-2T1.5BS-INT
9 A
Overload, normal duty
3G3M1-A2007Not listedMD520-2T1.5BS-INT
110% for 60 s
Maximum output frequency
3G3M1-A2007590 HzMD520-2T1.5BS-INT
599 Hz▲ 2%
Default carrier frequency
3G3M1-A2007Not listedMD520-2T1.5BS-INT
6 kHz
Enclosure
3G3M1-A2007IP20MD520-2T1.5BS-INT
IP20
Braking unit
3G3M1-A2007Not listedMD520-2T1.5BS-INT
Yes
Temperature derating
3G3M1-A2007Not listedMD520-2T1.5BS-INT
Above 40°C
Safe Torque Off
3G3M1-A2007YesMD520-2T1.5BS-INT
Yes
Control network
3G3M1-A2007MODBUS Slave, Serial RS-485, USBMD520-2T1.5BS-INT
Not listed
Communications options
3G3M1-A2007Not listedMD520-2T1.5BS-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink

▲ and ▼ show numerical differences. Check supply, configuration and installation before choosing.

Brand names and part numbers are used only to identify the products being compared. Universal Systems is not affiliated with or endorsed by these manufacturers. Comparisons use published specifications and are a starting point, not a confirmed replacement. Our engineers confirm suitability before any order.