Exact product photo on enquiry
RecommendedMD520-4T7.5BS-T-IP55-INT
Why this drive The original drive is rated at 16.5 A in heavy duty. This model supplies 17 A in heavy duty (7.5 kW nominal).
Published capacity covers 24.75 A for 60 s. Confirm repeat interval.
- Current
- 16.5 A · published
- Duty
- Heavy duty · default
- Supply
- 400 V AC · 3-phase
- Network
- Confirm at quotation
- Enclosure
- IP55
Edit Requirements
Installation Checks and Manuals
What to Confirm
- Keep IP55 protection at mounting and cable entries.
- Confirm the installed Ethernet or terminal control and any required EMC class and cable length.
- Confirm whether the installation requires UL Type 12 or another certification beyond IEC IP55.
- The comparison uses 400 V AC. Confirm the supply at your site.
- Verify the existing STO circuit, connections and required safety functions.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the overload repeat interval against the drive’s documented limits.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.