RecommendedMD520-4T1.1BS-INT
Why this drive The original drive is rated at 1.7 A in heavy duty. This model supplies 3.1 A in heavy duty (1.1 kW nominal).
Published capacity covers 3.4 A for 3 s and 2.55 A for 57 s. Confirm repeat interval.
- Current
- 1.7 A · published
- Duty
- Heavy duty · default
- Supply
- 400 V AC · 3-phase
- Network
- Confirm at quotation

MD520-4T1.5BS-INT
Capacity The original drive is rated at 1.7 A in heavy duty. This model supplies 3.8 A in heavy duty (1.5 kW nominal).
Published capacity covers 3.4 A for 3 s and 2.55 A for 57 s. Confirm repeat interval.
- Current
- 1.7 A · published
- Duty
- Heavy duty · default
- Supply
- 400 V AC · 3-phase
- Network
- Confirm at quotation

MD520-4T2.2BS-INT
Capacity The original drive is rated at 1.7 A in heavy duty. This model supplies 5.1 A in heavy duty (2.2 kW nominal).
Published capacity covers 3.4 A for 3 s and 2.55 A for 57 s. Confirm repeat interval.
- Current
- 1.7 A · published
- Duty
- Heavy duty · default
- Supply
- 400 V AC · 3-phase
- Network
- Confirm at quotation
Edit Requirements
Installation Checks and Manuals
What to Confirm
- Confirm the active network and motor rating. The stated overloads are successive segments of one 300-second cycle.
- The comparison uses 400 V AC. Confirm the supply at your site.
- Verify the existing STO circuit, connections and required safety functions.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the overload repeat interval against the drive’s documented limits.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.
Documents
MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFInovance MD520 international drives — A04 electrical model-pattern tablePDFWhat to Confirm
- Confirm the active network and motor rating. The stated overloads are successive segments of one 300-second cycle.
- The comparison uses 400 V AC. Confirm the supply at your site.
- Verify the existing STO circuit, connections and required safety functions.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the overload repeat interval against the drive’s documented limits.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.
Documents
MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFInovance MD520 international drives — A04 electrical model-pattern tablePDFWhat to Confirm
- Confirm the active network and motor rating. The stated overloads are successive segments of one 300-second cycle.
- The comparison uses 400 V AC. Confirm the supply at your site.
- Verify the existing STO circuit, connections and required safety functions.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the overload repeat interval against the drive’s documented limits.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.