Skip to catalogue results

Compare Inovance Options for ATV212HD30M3X

Official distributor for Australia and New Zealand
Inovance MD520 family illustration
Illustration

MD520-2T37BS-INT

Why this drive The original drive is rated at 117 A in altivar 212 variable torque. This model supplies 150 A in heavy duty (37 kW nominal).

Published capacity covers 128.7 A for 60 s and 210.6 A for 2 s. Confirm repeat interval.

Current
117 A · published
Duty
Altivar 212 variable torque
Supply
230 V AC · 3-phase
Network
Confirm at quotation
Temperature
40 °C · rating basis
Review Full Comparison
Edit Requirements
Temperature, Altitude and Overload

Enter peak current and duration together to use the machine’s own overload requirement.

Installation Checks and Manuals

What to Confirm

  • Confirm any optional Type 1 kit and the installed HVAC network protocol.
  • Review the HVAC controls, EMC filter and motor nameplate at the site switching frequency.
  • The comparison uses 230 V AC. Confirm the supply at your site.
  • Confirm whether the existing installation uses a drive safety function.
  • Confirm the required enclosure rating and cabinet protection.
  • Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
  • Confirm the overload repeat interval against the drive’s documented limits.
  • Confirm site temperature and altitude.
  • Confirm the switching frequency used for the published rating.
  • Confirm motor nameplate and braking requirements before ordering.

Documents

MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDF

Full Specification Comparison

SpecificationATV212HD30M3X
Supply voltage
ATV212HD30M3X200–240 V ACMD520-2T37BS-INT
200–240 V AC
Input phases
ATV212HD30M3X3MD520-2T37BS-INT
3
Motor power, heavy duty
ATV212HD30M3XNot listedMD520-2T37BS-INT
37 kW
Output current, heavy duty
ATV212HD30M3XNot listedMD520-2T37BS-INT
150 A
Overload, heavy duty
ATV212HD30M3XNot listedMD520-2T37BS-INT
150% for 60 s
Motor power, normal duty
ATV212HD30M3XNot listedMD520-2T37BS-INT
45 kW
Output current, normal duty
ATV212HD30M3XNot listedMD520-2T37BS-INT
176 A
Overload, normal duty
ATV212HD30M3XNot listedMD520-2T37BS-INT
110% for 60 s
Published motor power
ATV212HD30M3X30 kWMD520-2T37BS-INT
Not listed
Published output current
ATV212HD30M3X117 AMD520-2T37BS-INT
Not listed
Maximum output frequency
ATV212HD30M3XNot listedMD520-2T37BS-INT
599 Hz
Default carrier frequency
ATV212HD30M3XNot listedMD520-2T37BS-INT
3 kHz
Enclosure
ATV212HD30M3XIP20 open style; optional Type1 kitMD520-2T37BS-INT
Not listed
Braking unit
ATV212HD30M3XNot listedMD520-2T37BS-INT
Yes
Temperature derating
ATV212HD30M3XNot listedMD520-2T37BS-INT
Above 40°C
Safe Torque Off
ATV212HD30M3XNot listedMD520-2T37BS-INT
Yes
Control network
ATV212HD30M3XModbus, BACnet, Metasys N2, Apogee P1; exact configuration requiredMD520-2T37BS-INT
Not listed
Communications options
ATV212HD30M3XBACnetMD520-2T37BS-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink

▲ and ▼ show numerical differences. Check supply, configuration and installation before choosing.

Brand names and part numbers are used only to identify the products being compared. Universal Systems is not affiliated with or endorsed by these manufacturers. Comparisons use published specifications and are a starting point, not a confirmed replacement. Our engineers confirm suitability before any order.