RecommendedMD520-2T37BS-INT
Why this drive The original drive is rated at 90 A in mitsubishi normal duty (ND at 50 °C). This model supplies 127.5 A in heavy duty (37 kW nominal) after derating.
Timed overload at this temperature or altitude needs confirmation.
- Current
- 90 A · published
- Duty
- Mitsubishi normal duty (ND at 50 °C)
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation
- Temperature
- 50 °C · rating basis

MD520-2T45S-INT
Capacity The original drive is rated at 90 A in mitsubishi normal duty (ND at 50 °C). This model supplies 149.6 A in heavy duty (45 kW nominal) after derating.
Timed overload at this temperature or altitude needs confirmation.
- Current
- 90 A · published
- Duty
- Mitsubishi normal duty (ND at 50 °C)
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation
- Temperature
- 50 °C · rating basis

MD520-2T55S-INT
Capacity The original drive is rated at 90 A in mitsubishi normal duty (ND at 50 °C). This model supplies 178.5 A in heavy duty (55 kW nominal) after derating.
Timed overload at this temperature or altitude needs confirmation.
- Current
- 90 A · published
- Duty
- Mitsubishi normal duty (ND at 50 °C)
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation
- Temperature
- 50 °C · rating basis
Edit Requirements
Installation Checks and Manuals
What to Confirm
- Confirm the exact FR-E800 interface and safety functions, fitted braking hardware and the installed duty setting.
- The comparison uses 230 V AC. Confirm the supply at your site.
- Confirm whether the existing installation uses a drive safety function.
- Confirm the required enclosure rating and cabinet protection.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Verify timed overload at the derated operating point.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.
Documents
MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFWhat to Confirm
- Confirm the exact FR-E800 interface and safety functions, fitted braking hardware and the installed duty setting.
- The comparison uses 230 V AC. Confirm the supply at your site.
- Confirm whether the existing installation uses a drive safety function.
- Confirm the required enclosure rating and cabinet protection.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Verify timed overload at the derated operating point.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.
Documents
MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFWhat to Confirm
- Confirm the exact FR-E800 interface and safety functions, fitted braking hardware and the installed duty setting.
- The comparison uses 230 V AC. Confirm the supply at your site.
- Confirm whether the existing installation uses a drive safety function.
- Confirm the required enclosure rating and cabinet protection.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Verify timed overload at the derated operating point.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.