MD520-2T18.5BS-INT

Why this drive The original drive is rated at 47 A in mitsubishi normal duty (ND at 50 °C). This model supplies 63.75 A in heavy duty (18.5 kW nominal) after derating.

Timed overload at this temperature or altitude needs confirmation.

Current
47 A · published
Duty
Mitsubishi normal duty (ND at 50 °C)
Supply
230 V AC · 3-phase
Network
Confirm at quotation
Temperature
50 °C · rating basis
Review Full Comparison
Edit Requirements
Temperature, Altitude and Overload

Enter peak current and duration together to use the machine’s own overload requirement.

Installation Checks and Manuals

What to Confirm

  • Confirm the exact FR-E800 interface and safety functions, fitted braking hardware and the installed duty setting.
  • The comparison uses 230 V AC. Confirm the supply at your site.
  • Confirm whether the existing installation uses a drive safety function.
  • Confirm the required enclosure rating and cabinet protection.
  • Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
  • Verify timed overload at the derated operating point.
  • Confirm site temperature and altitude.
  • Confirm the switching frequency used for the published rating.
  • Confirm motor nameplate and braking requirements before ordering.

Documents

MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDF

Full Specification Comparison

SpecificationFR-E820-0470
Supply voltage
FR-E820-0470200–240 V ACMD520-2T18.5BS-INT
200–240 V AC
MD520-2T22BS-INT
200–240 V AC
MD520-2T30BS-INT
200–240 V AC
Input phases
FR-E820-04703MD520-2T18.5BS-INT
3
MD520-2T22BS-INT
3
MD520-2T30BS-INT
3
Motor power, heavy duty
FR-E820-0470Not listedMD520-2T18.5BS-INT
18.5 kW
MD520-2T22BS-INT
22 kW
MD520-2T30BS-INT
30 kW
Output current, heavy duty
FR-E820-0470Not listedMD520-2T18.5BS-INT
75 A
MD520-2T22BS-INT
91 A
MD520-2T30BS-INT
112 A
Overload, heavy duty
FR-E820-0470Not listedMD520-2T18.5BS-INT
150% for 60 s
MD520-2T22BS-INT
150% for 60 s
MD520-2T30BS-INT
150% for 60 s
Motor power, normal duty
FR-E820-047011 kWMD520-2T18.5BS-INT
22 kW
MD520-2T22BS-INT
30 kW
MD520-2T30BS-INT
37 kW
Output current, normal duty
FR-E820-0470Not listedMD520-2T18.5BS-INT
91 A
MD520-2T22BS-INT
112 A
MD520-2T30BS-INT
150 A
Overload, normal duty
FR-E820-0470Not listedMD520-2T18.5BS-INT
110% for 60 s
MD520-2T22BS-INT
110% for 60 s
MD520-2T30BS-INT
110% for 60 s
Published output current
FR-E820-047047 AMD520-2T18.5BS-INT
Not listed
MD520-2T22BS-INT
Not listed
MD520-2T30BS-INT
Not listed
Maximum output frequency
FR-E820-0470Not listedMD520-2T18.5BS-INT
599 Hz
MD520-2T22BS-INT
599 Hz
MD520-2T30BS-INT
599 Hz
Default carrier frequency
FR-E820-0470Not listedMD520-2T18.5BS-INT
5 kHz
MD520-2T22BS-INT
5 kHz
MD520-2T30BS-INT
4 kHz
Enclosure
FR-E820-0470IP20open typeMD520-2T18.5BS-INT
Not listed
MD520-2T22BS-INT
Not listed
MD520-2T30BS-INT
Not listed
Braking unit
FR-E820-0470Not listedMD520-2T18.5BS-INT
Yes
MD520-2T22BS-INT
Yes
MD520-2T30BS-INT
Yes
Temperature derating
FR-E820-0470Not listedMD520-2T18.5BS-INT
Above 40°C
MD520-2T22BS-INT
Above 40°C
MD520-2T30BS-INT
Above 40°C
Safe Torque Off
FR-E820-0470Not listedMD520-2T18.5BS-INT
Yes
MD520-2T22BS-INT
Yes
MD520-2T30BS-INT
Yes
Communications options
FR-E820-0470Not listedMD520-2T18.5BS-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink
MD520-2T22BS-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink
MD520-2T30BS-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink

▲ and ▼ show numerical differences. Check supply, configuration and installation before choosing.

Brand names and part numbers are used only to identify the products being compared. Universal Systems is not affiliated with or endorsed by these manufacturers. Comparisons use published specifications and are a starting point, not a confirmed replacement. Our engineers confirm suitability before any order.