RecommendedMD520-2T0.4BS-INT
Why this drive The original drive is rated at 1 A in hHD · heavy load. This model supplies 2.1 A in heavy duty (0.4 kW nominal).
Published capacity covers 1.5 A for 60 s and 2 A for 0.5 s. Confirm repeat interval.
- Current
- 1 A · published
- Duty
- HHD · heavy load · default
- Supply
- 230 V AC · 3-phase
- Network
- Confirm at quotation
- Temperature
- 40 °C · rating basis
Edit Requirements
Installation Checks and Manuals
What to Confirm
- Verify the motor type, encoder and control functions, braking circuit, cooling and switching frequency before ordering.
- Check the existing EMC class, cable length and earthing arrangement.
- Confirm the selected Omron duty and its ambient-temperature and carrier-frequency limits.
- The comparison uses 230 V AC. Confirm the supply at your site.
- Verify the existing STO circuit, connections and required safety functions.
- Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
- Confirm the overload repeat interval against the drive’s documented limits.
- Confirm site temperature and altitude.
- Confirm the switching frequency used for the published rating.
- Confirm motor nameplate and braking requirements before ordering.