Skip to catalogue results

Compare Inovance Options for ATV630C16N4

Official distributor for Australia and New Zealand
Inovance MD520-4T132S-INT
Illustration

MD520-4T132S-INT

Why this drive The original drive is rated at 240 A in heavy duty. This model supplies 253 A in heavy duty (132 kW nominal).

Current
240 A · published
Duty
Heavy duty · default
Supply
400 V AC · 3-phase
Network
Confirm at quotation
Review Full Comparison
Edit Requirements
Temperature, Altitude and Overload

Enter peak current and duration together to use the machine’s own overload requirement.

Installation Checks and Manuals

What to Confirm

  • The comparison uses 400 V AC. Confirm the supply at your site.
  • Confirm whether the existing installation uses a drive safety function.
  • Confirm the required enclosure rating and cabinet protection.
  • Confirm the installed control protocol, or choose No fieldbus in use if the drive uses terminal control.
  • Confirm the peak current, duration and overload repeat interval.
  • Confirm site temperature and altitude.
  • Confirm the switching frequency used for the published rating.
  • Confirm motor nameplate and braking requirements before ordering.

Documents

MD520-INT — exact voltage/power options, HD/ND current and carrier-frequency tablesPDFMD520 Installation Guide B01PDFInovance MD520 international drives — A04 electrical model-pattern tablePDF

Full Specification Comparison

SpecificationATV630C16N4
Supply voltage
ATV630C16N4380–480 V ACMD520-4T132S-INT
380–480 V AC
MD520-4T160S-INT
380–480 V AC
MD520-4T200S-INT
380–480 V AC
Input phases
ATV630C16N43MD520-4T132S-INT
3
MD520-4T160S-INT
3
MD520-4T200S-INT
3
Motor power, heavy duty
ATV630C16N4132 kWMD520-4T132S-INT
132 kW
MD520-4T160S-INT
160 kW
MD520-4T200S-INT
200 kW
Output current, heavy duty
ATV630C16N4240 AMD520-4T132S-INT
253 ARecommended
MD520-4T160S-INT
304 AOne size up
MD520-4T200S-INT
377 ATwo sizes up
Overload, heavy duty
ATV630C16N4Not listedMD520-4T132S-INT
150% for 60 s
MD520-4T160S-INT
150% for 60 s
MD520-4T200S-INT
150% for 60 s
Motor power, normal duty
ATV630C16N4160 kWMD520-4T132S-INT
160 kW
MD520-4T160S-INT
200 kW
MD520-4T200S-INT
250 kW
Output current, normal duty
ATV630C16N4302 AMD520-4T132S-INT
304 A
MD520-4T160S-INT
377 A
MD520-4T200S-INT
465 A
Overload, normal duty
ATV630C16N4Not listedMD520-4T132S-INT
110% rated current for 60 s or 110% for60s
MD520-4T160S-INT
110% rated current for 60 s or 110% for60s
MD520-4T200S-INT
110% rated current for 60 s or 110% for60s
Motor power, light duty
ATV630C16N4Not listedMD520-4T132S-INT
160 kW
MD520-4T160S-INT
200 kW
MD520-4T200S-INT
250 kW
Output current, light duty
ATV630C16N4Not listedMD520-4T132S-INT
304 A
MD520-4T160S-INT
377 A
MD520-4T200S-INT
465 A
Maximum output frequency
ATV630C16N4Not listedMD520-4T132S-INT
599 Hz
MD520-4T160S-INT
599 Hz
MD520-4T200S-INT
599 Hz
Default carrier frequency
ATV630C16N4Not listedMD520-4T132S-INT
3 kHz
MD520-4T160S-INT
3 kHz
MD520-4T200S-INT
3 kHz
Enclosure
ATV630C16N4Not listedMD520-4T132S-INT
IP20
MD520-4T160S-INT
IP20
MD520-4T200S-INT
IP00
Braking unit
ATV630C16N4Not listedMD520-4T132S-INT
No
MD520-4T160S-INT
No
MD520-4T200S-INT
No
Temperature derating
ATV630C16N4Not listedMD520-4T132S-INT
Above 40°C
MD520-4T160S-INT
Above 40°C
MD520-4T200S-INT
Above 40°C
Safe Torque Off
ATV630C16N4Not listedMD520-4T132S-INT
Yes
MD520-4T160S-INT
Yes
MD520-4T200S-INT
Yes
Communications options
ATV630C16N4Not listedMD520-4T132S-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink
MD520-4T160S-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink
MD520-4T200S-INT
PROFINET · EtherNet/IP · EtherCAT · CANopen · Modbus RTU · Modbus TCP · PROFIBUS-DP · CANlink

▲ and ▼ show numerical differences. Check supply, configuration and installation before choosing.

Brand names and part numbers are used only to identify the products being compared. Universal Systems is not affiliated with or endorsed by these manufacturers. Comparisons use published specifications and are a starting point, not a confirmed replacement. Our engineers confirm suitability before any order.