| Electrical & performance |
|---|
| AC supply voltage | 380 · 480 V AC nominal mains class used conservatively for shortlist; not the full tolerance intervalSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Shared technical-specification row explicitly scoped to400Vmodels · A00 indexed TechnicalSpecifications,Basicfunctions,printedp16;400Vrows only; Shared technical-specification row explicitly scoped to400Vmodels. No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition. · No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition.
|
|---|
| Input phases | 3Source & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Shared technical-specification row explicitly scoped to400Vmodels · A00 indexed TechnicalSpecifications,Basicfunctions,printedp16;400Vrows only; Shared technical-specification row explicitly scoped to400Vmodels. No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition. · No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition.
|
|---|
| Motor power | 220 kW; conservative HD column used for provisional shortlist; not LDSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Output current | 426 A; conservative HD motor-output current used for provisional shortlist; not mains/LD/code digitsSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Overload | View structured source values- Light duty
- 110% for1minute every5minutes
- Heavy duty
- 150% for1minute every5minutes
Source & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Shared technical-specification row explicitly scoped to400Vmodels · A00 indexed TechnicalSpecifications,Basicfunctions,printedp16;400Vrows only; Shared technical-specification row explicitly scoped to400Vmodels. No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition. · No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition.
|
|---|
| Motor power · heavy duty | 220 kW; HD columnSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Output current · heavy duty | 426 A; HD motor output currentSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Heavy duty input current (A) | 410 A; HD mains input currentSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Light duty input current (A) | 456 A; LD mains input currentSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Motor power · light duty | 250 kW; LD columnSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Output current · light duty | 465 A; LD motor output currentSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|
| Maximum output frequency (Hz) | 599 Hz; V/f and vector family limitSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Shared technical-specification row explicitly scoped to400Vmodels · A00 indexed TechnicalSpecifications,Basicfunctions,printedp16;400Vrows only; Shared technical-specification row explicitly scoped to400Vmodels. No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition. · No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition.
|
|---|
| Nominal input voltage class (V AC) | 380 · 480 V AC nominal400V classSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Shared technical-specification row explicitly scoped to400Vmodels · A00 indexed TechnicalSpecifications,Basicfunctions,printedp16;400Vrows only; Shared technical-specification row explicitly scoped to400Vmodels. No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition. · No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition.
|
|---|
| Permissible input voltage fluctuation (V AC) | 323 · 528 V AC; source explicitly prints tolerated interval,-15%/+10%; not full-rated-output guarantee throughoutSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Shared technical-specification row explicitly scoped to400Vmodels · A00 indexed TechnicalSpecifications,Basicfunctions,printedp16;400Vrows only; Shared technical-specification row explicitly scoped to400Vmodels. No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition. · No tolerance arithmetic inferred:323–528VAC is printed by manufacturer.690V525–690VAC/446–759VAC not applied.0.8–12kHz carrier is model-dependent and not assigned as a per-model rated-current condition.
|
|---|
| Control & interfaces |
|---|
| Safe Torque Off recorded | YesSource & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Explicit international400Vseries nomenclature and standardSTOnote · A00 indexed OrderingCode,printedp10;INTvariant,4Tvoltageclass,-L andSTOnote; Explicit international400Vseries nomenclature and standardSTOnote. STO presence only; no safety-level,certification,installedcircuit orapplicationapproval asserted. NoDCreactorclaim inferred from-L. Actualsuppliedrevision andsafetymanual must be reviewed. · STO presence only; no safety-level,certification,installedcircuit orapplicationapproval asserted. NoDCreactorclaim inferred from-L. Actualsuppliedrevision andsafetymanual must be reviewed.
|
|---|
| Additional product data |
|---|
| Target rating basis | Heavy-duty motorpower and heavy-duty motoroutputcurrent from the SAME exact row used together. LD ratings retained separately; no factoryduty or actualconfiguredmode inferred.Source & conditions- Revision
- 19120556 A00; filename30April2025; indexed excerpts reviewed, fullPDF unavailable
- Applies to
- Exact international model table row; two independent duty operating points · A00 Specifications–400VModels:literal MD580-*-INT 4T465-L row, LD then HD columns; fulltablepage not exposed by index; Exact international model table row; two independent duty operating points. LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit. · LD/HD andinput/output currents kept separate. -L is the explicit outputACreactor option onT10–T12; not inferred asDC/inputreactor. Optionalexternalreactorpart tables are not approvedBOMs. No600/690V model transfer orA01 electrical-table substitution. Missingfullfile/tablepage/ambient/currentderating remain explicit.
|
|---|