Skip to catalogue results
Back to products
Product tools

Your selected products

Compare Selected Parts

Add up to four products of the same type. The first column is the reference; this compares specifications without establishing equivalence, compatibility or a motor/drive pairing.

1 of 4 selectedAdd another product Clear comparison

One part selected. Add another product of the same type to compare it side by side.

SpecificationsDifferent recorded valueYour reference
Inovance GL20-1DNM-INT

GL20-1DNM-INT

Brand
Inovance
Family
GL20
View details →
Remove
Installation & mechanics
IP rating
IP20
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Additional product data
Product role
Communication expansion module
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
More specifications & source notes 8 additional fields
FeatureGL20-1DNM-INT
Electrical & performance
Source module power
100 mA; brochure label retained
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Control & interfaces
Source communication channels
1 CAN physical communication channel; protocol compatibility not established by this table
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Installation & mechanics
Dimensions
24×100×75 mm;W×H×D
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Additional product data
Operating temperature
−20–55 °C; 10–90% RH, non-condensing
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source can baud rates
125; 250; 500 kbit/s; default 125
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source slave limit
63 maximum
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source supported couplers
GL20-RTU-ECT32-INT; only for Inovance PLC
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source termination
Supported; short R+ and R− terminals per guide
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.

Source-specific values, duties and revisions remain separate. Matching values do not establish suitability. Family illustrations may differ from the exact enclosure. These are user selections, not a saved replacement recommendation.