Inovance GL20-1DNM-INT

Manufacturer illustration. Confirm the exact physical variant.

Inovance / Remote I/O

GL20-1DNM-INT

Remote I/O

Brand
Inovance
Family
GL20
Product type
Remote I/O

Price, availability and application suitability are confirmed by our team.

Technical Specifications

Check the listed ratings and operating conditions for your application before ordering.

FeatureDocumented value
Installation & mechanics
IP rating
IP20
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Additional product data
Product role
Communication expansion module
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
More specifications & source notes 8 additional fields
FeatureDocumented value
Electrical & performance
Source module power
100 mA; brochure label retained
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Control & interfaces
Source communication channels
1 CAN physical communication channel; protocol compatibility not established by this table
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Installation & mechanics
Dimensions
24×100×75 mm;W×H×D
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Additional product data
Operating temperature
−20–55 °C; 10–90% RH, non-condensing
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source can baud rates
125; 250; 500 kbit/s; default 125
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source slave limit
63 maximum
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source supported couplers
GL20-RTU-ECT32-INT; only for Inovance PLC
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.
Source termination
Supported; short R+ and R− terminals per guide
Source & conditions
Revision
19120523-CY A01, 28 August2025
Applies to
Exact literal INT model table in A01 brochure · GL20-1DNM-INT; PDF page16; no transfer to other model or material · A01 exact table scope only. Installation, power budget, firmware, coupler and delivered revision must be checked. No stock, certification approval or automatic substitution.

Documents & Sources

Check that the document covers your exact model and revision.

Datasheet / brochure · GL20

Inovance GL20-INT I/O system brochure A01 ↗

Revision
A01
Linked parts
35
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=16

Original manufacturer reference: Source 1 ↗ Source 2 ↗ Source 3 ↗ Source 4 ↗ Source 5 ↗ Source 6 ↗ Source 7 ↗ Source 8 ↗ Source 9 ↗ Source 10 ↗ Source 11 ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Datasheet / brochure

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team