Skip to catalogue results
Back to product family
Product tools
Inovance EASY301-0808TN-INT

Manufacturer illustration. Confirm the exact physical variant.

Inovance / Programmable controller

EASY301-0808TN-INT

Machine controller range

Brand
Inovance
Product type
Programmable controller

Price, availability and application suitability are confirmed by our team.

Technical Specifications

Published specifications. Check the model configuration, duty rating and source conditions before ordering.

FeatureDocumented value
Electrical & performance
DC supply voltage
21.6 · 26.4 VDC; terminal input allowable range,24Vnominal
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Nominal supply (V DC)
24 V DC nominal; brochure does not state allowed interval
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Terminal power input current (A)
1 A maximum at24V; not output-channel current
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Control & interfaces
Digital inputs
8
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Digital outputs
8
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Communications
RS232/RS485 Modbus RTU/ASC/free protocol; no built-in Ethernet/EtherCAT in reviewed table. No GE20 expansion slot.
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Ethernet ports
0
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Engineering software
AutoShop; actual supported version,program conversion and licence conditions require review
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Additional product data
Easy global feature scope note

Multiple published values — check sources

The global exact-product page repeats family-wide32-axis,dualEthernet andtwo-expansion-slot marketing. Those features are not assigned to this exact model from the page. Use independent model-column/manual evidence and actual firmware; no stock or engineering approval.
Source & conditions
Revision
Global page accessed26October2026; revision unstated
Applies to
Exact identity only; feature scope withheld · Literal exact INT product title and repeated family feature text; Exact identity only; feature scope withheld. No EtherCAT count,PNP/NPN polarity,I/O count,firmware,stock or supplied-version rating inferred from the family marketing text. · No EtherCAT count,PNP/NPN polarity,I/O count,firmware,stock or supplied-version rating inferred from the family marketing text.
Global exact301page repeats familydualEthernet and32-axis statements; A05 exact301hardware explicitly has noEthernet andmaximumfourlocalpulseaxes. A05 also mentions16virtualaxes; virtualaxes are not16physicalEtherCATaxes. Global generic claims withheld from exact technical fields.
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Program capacity ksteps
128 ksteps; brochure source unit, not MB or common instruction capacity
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Serial interfaces
One RS232 and one RS485; Modbus RTU/ASC and free protocol
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Target identity scope

Multiple published values — check sources

Existing supplier international code is explicitly named in the global manufacturer product title; case retained from supplier record. No INT suffix fabricated or domestic alias created.
Source & conditions
Revision
Global page accessed26October2026; revision unstated
Applies to
Exact identity only; feature scope withheld · Literal exact INT product title and repeated family feature text; Exact identity only; feature scope withheld. No EtherCAT count,PNP/NPN polarity,I/O count,firmware,stock or supplied-version rating inferred from the family marketing text. · No EtherCAT count,PNP/NPN polarity,I/O count,firmware,stock or supplied-version rating inferred from the family marketing text.
Existing supplier EASY301-0808TN-INT explicitly confirmed by exact global title; A05 and EUV0.2 base hardware are associated conditionally, not domestic aliases.
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
More specifications & source notes 20 additional fields
FeatureDocumented value
Electrical & performance
Expansion bus power scope
5VDC bus output,1Atypical; total expansion module rated bus-input current must not exceed1A; eight-module count alone does not prove load budget.
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
High speed input channels
8
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
High speed input frequency (kHz)
200 kHz single-phase input scope
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
High speed pulse output channels
4
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
High speed pulse output frequency (kHz)
200 kHz forresistiveload; Y0–Y3; not all8outputs
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Control & interfaces
Custom variable storage (MB)
1 MB includes128kB retentive; A05
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Data storage mbyte
1 Mbyte; source storage scope retained,128KB nonvolatile stated separately
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Digital output type
NPN sink transistor
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Nonvolatile data storage (kB)
128 KB; subset, not all data retentive
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Output load bands
View structured source values
Y0 Y3 high speed
Resistive per point (A)
0.5
Source group scope
2A/8-point as printed
Inductive per point (W)
7.2
Inductive 8 point (W)
24
Lamp per point (W)
5
Lamp 8 point (W)
18
Minimum load at above10khz (mA)
12
Y4 Y7 normal
Resistive per point (A)
0.5
Resistive common terminal (A)
1
Inductive total at24v (W)
6
Lamp total at24v (W)
1
Resistive max frequency (Hz)
100
Minimum load (mA)
5
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Program memory source text
A05 PDFp15 prints user program128 kB steps. Mixed unit retained verbatim; no conversion tobytes/MB or silent correction. EUV0.2 independently states128Ksteps.
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Soft element storage scope
Approximately150kB; retentive afterNo.1000 at power failure; nonretentive if powered only byUSB
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Additional product data
Easy hardware scope note
European V0.2 literal base EASY301-0808TN TN column is associated only with this existing supplier INT record. Exact installed/supplied international hardware and firmware must be checked. No PNPTP,Easy521/522 or neighbouring-model ratings transferred. Brochure is a regional/revision scope, not supply approval.
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Ethercat axes
0
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Expansion card slots
0
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Installation temperature scope
Horizontal:-20to55C; nonhorizontal:-20to45C. Horizontal full input load at45C; at55C at mostsixofeight active inputs(75%). See A05 full installation limits.
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.
Max local expansion modules
8
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Maximum pulse control axes
4
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Outline W H D (mm)
24 · 100 · 83 mm; width,height,depth
Source & conditions
Revision
European English brochure V0.2; publication date not stated
Applies to
Explicit base TN model column associated with existing supplier INT record · V0.2 PDFp5 printed8–9, exact EASY301-0808TN column and explicitly common rows; Explicit base TN model column associated with existing supplier INT record. Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred. · Compare actual model and firmware. No TNtoTP transfer or 521/522 transfer. Program/data units and nominal-only supply retained. Optional CAN and software/network functions require hardware/revision review. Axis budgets not added together; no equivalence or Australian stock inferred.
Programming language revision scope
A05 PDFp16 lists LD,SFC andFB/FC(LD); EUV0.2 printed8–9 lists LD,SFC,ST,FB/FC. ST support is revision-dependent/unresolved for actual firmware; do not promise from generic current global marketing.
Source & conditions
Revision
PS00006239 A05; revision history July2024
Applies to
Exact Easy301 base TN hardware associated with existing literal INT record · A05 PDFp15–19 printed13–17 model-specific specifications; PDFp20–21 printed18–19 installation; Exact Easy301 base TN hardware associated with existing literal INT record. A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer. · A05 July2024 revision retained. No output-current group simplification,softwarefeature promise or virtual-to-physicalaxis conversion. Footnotes/load type,terminal groups and temperature/active-input derating remain mandatory. No catalogue-wide transfer.

Documents & Sources

Linked to EASY301-0808TN-INT. Confirm the revision and exact variant inside the source.

Open this part’s document library →

Manual · Easy Series

Inovance EASY301 PLC user guide A11 ↗

Revision
A11
Linked parts
1
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=21

Original manufacturer reference: View source ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Manual
Separate family references · check exact-variant applicability

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team