Skip to catalogue results
Back to product family
Product tools
Inovance ISMG2 standard motor frame drawing

Manufacturer ISMG2 frame drawing. Check model length and mounting feet.

Inovance / Servo motor

ISMG2-57D20CD-A331FA-INT

Servo motor

Brand
Inovance
Family
ISMG2
Product type
Servo motor

Price, availability and application suitability are confirmed by our team.

Technical Specifications

Check the listed ratings and operating conditions for your application before ordering.

FeatureDocumented value
Electrical & performance
Ismg2 a00 max current (A)
207.8 A; published basis
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 max speed flux weakening off (rpm)
2200 rpm
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 max speed flux weakening on (rpm)
3000 rpm
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 max torque (N·m)
440 N·m; maximum duration/load cycle not approved
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 rated motor voltage v
380 V; motor rating, not drive mains input
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 rated speed (rpm)
2000 rpm
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 s1 current (A)
93.1 A; published basis
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 s1 power (kW)
48.2 kW; S1 continuous
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 s1 torque (N·m)
230 N·m; S1 continuous
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 s4 current (A)
109.3 A; published basis
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 s4 power (kW)
56.5 kW; S4 intermittent
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 s4 torque (N·m)
270 N·m; S4 intermittent
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Installation & mechanics
Ismg2 a00 dimension L (mm)
577 mm; source drawing lengthL
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 mounting foot pitch K (mm)
370 mm; source definesK as distance between mounting feet
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 net weight kg
141.3 kg
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 rotor inertia kgcm2
368 kg·cm²
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Additional product data
Ismg2 a00 scope note
Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.
Ismg2 a00 source header conflict
G2section/stem/dimension-table match; repeated technical header saysISMG1. Source inconsistency retained; no automatic canonical rating promotion.
Source & conditions
Revision
A00; filename30December2024; data code19120515-CY
Applies to
Source-qualified G2 technical and dimensional scope; no replacement, motor-drive pairing or availability approval · Primaryglobal ISMG-INTA00 brochure section"Performance Parameters of ISMG Series G2 Motors", matched exact57D20CD column and standard dimension table. Important source discrepancy: the printed/extracted repeated specification header saysISMG1-*******-**3**A-INT even in the G2 section. The G2section heading,266mm frame drawing and fullISMG2literal dimension codes identify this as G2scope, but the inconsistent header remains explicit. These source-qualified attributes do not silently replace canonical electrical ratings or approve an exact installed motor/drive system. The document distinguishes continuousS1 from intermittentS4 and flux-weakening-ON/OFF speed maxima. PublishedAcurrent basis is not labelledRMSorpeakamplitudehere; no conversion is inferred. Actual thermalcurve,fanpower/cooling,loadcycle,speedenvelope,encoder/cables,footmounting and local supply need review.

Documents & Sources

Check that the document covers your exact model and revision.

Manufacturer technical reference · ISMG1 high-power servo motors, ISMG2

Inovance ISMG-INT General-Purpose High-Power Servo Motor Brochure — A00 global S1/S4 specification tables ↗

Revision
A00; filename30December2024; data code19120515-CY
Linked parts
5
View linked partsSource association does not confirm suitability for every variant. Check model coverage inside the document.
Manufacturer technical reference

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team