Inovance GS20-ECT-8L-INT

Manufacturer illustration. Confirm the exact physical variant.

Inovance / Remote I/O

GS20-ECT-8L-INT

Remote I/O

Brand
Inovance
Family
GS20
Product type
Remote I/O

Price, availability and application suitability are confirmed by our team.

Technical Specifications

Published specifications. Check the model configuration, duty rating and source conditions before ordering.

FeatureDocumented value
Electrical & performance
DC supply voltage
24 V DC
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Output current per point sio (A)
2 A maximum per point in SIO mode only
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Control & interfaces
Communications
EtherCAT
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Installation & mechanics
Ingress protection
IP67
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Additional product data
Product role
EtherCAT IO-Link master
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
More specifications & source notes 10 additional fields
FeatureDocumented value
Additional product data
Depth (mm)
20.5 mm; D in H×W×D
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Ethercat connection connector
4-pin M12 D-code
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Height (mm)
224.8 mm; H in H×W×D
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
I/O link master ports
8 Class A ports
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
I/O link port class
CLASS A
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
I/O link signal connector
5-pin M12 A-code
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
I/O link transmission rates
COM1 4.8kbaud; COM2 38.4kbaud; COM3 230.4kbaud
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
I/O link version
V1.1
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Operating temperature c
-25 · 70 deg C; brochure operating range
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
Width (mm)
69.8 mm; W in H×W×D
Source & conditions
Revision
19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
Applies to
Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.

Documents & Sources

Linked to GS20-ECT-8L-INT. Confirm the revision and exact variant inside the source.

Open this part’s document library →

Datasheet / brochure · GR20, GS20

Inovance GS20 and GR20-INT IO-Link brochure A01 ↗

Revision
A01
Linked parts
5
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=2

Exact part reference: page=2

Original manufacturer reference: View source ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Datasheet / brochure

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team