| Additional product data |
|---|
| Depth (mm) | 20.5 mm; D in H×W×DSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| Ethercat connection connector | 4-pin M12 D-codeSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| Height (mm) | 224.8 mm; H in H×W×DSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| I/O link master ports | 8 Class A portsSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| I/O link port class | CLASS ASource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| I/O link signal connector | 5-pin M12 A-codeSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| I/O link transmission rates | COM1 4.8kbaud; COM2 38.4kbaud; COM3 230.4kbaudSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| I/O link version | V1.1Source & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| Operating temperature c | -25 · 70 deg C; brochure operating rangeSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|
| Width (mm) | 69.8 mm; W in H×W×DSource & conditions- Revision
- 19120524 A01; archived filename dated20250828; later manual revisions are separate evidence
- Applies to
- Exact literal INT model column in retained A01 brochure · PDF page2, IO-Link Master GS20 table, single literal GS20-ECT-8L-INT model · A01 brochure operating scope only. Exact offered revision, mounting, cables/connectors, power budget and application conditions require review. No stock, pairing or compliance approval. The 2A current point applies to SIO mode; no aggregate or IO-Link supply-current claim inferred.
|
|---|