Skip to catalogue results
Back to product family
Product tools
Inovance GL20-0004ETP-2A-INT

Manufacturer illustration. Confirm the exact physical variant.

Inovance / Remote I/O

GL20-0004ETP-2A-INT

Remote I/O

Brand
Inovance
Family
GL20
Product type
Remote I/O

Price, availability and application suitability are confirmed by our team.

Technical Specifications

Check the listed ratings and operating conditions for your application before ordering.

FeatureDocumented value
Electrical & performance
Equipment output current scope
At45C the total simultaneously ON current may reach8A; at55C it is limited to5A. Screening uses the lower5A module budget, retaining2A/point and4physical channels. The guide gives50microampere OFF leakage; the older brochure50milliampere wording is not applied to this newly qualified material. Actual24V field voltage,load resistance,diagnostics and inrush must be checked.
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Equipment output field voltage (V DC)
20.4 · 28.8 V DC
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Equipment output module current 45c (A)
8 A
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Equipment output module current 55c (A)
5 A
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Equipment output point current (A)
2 A; resistive, nominal24V application
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Control & interfaces
Digital outputs
4 count
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Output polarity
PNP
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Installation & mechanics
Ingress protection
IP20
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp8; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
Additional product data
A01 supported coupler codes
GL20-RTU-ECT32-INT · GL20-RTU-EIP-INT · GL20-RTU-PN-INT
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Exact INT brochure model-name association; firmware applicability remains conditional · PDF9 exact INT module table and supported-coupler row; Exact INT brochure model-name association; firmware applicability remains conditional. Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability. · Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability.
Equipment guide required material code
01441059
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
Manufacturer material code
01440787
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
More specifications & source notes 16 additional fields
FeatureDocumented value
Electrical & performance
Equipment output switching frequency (Hz)
View structured source values
Resistive load
100
Inductive load
0.5
Lamp load
10
Hz; load-specific maximum
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Literal equipment guide technical table · A00 PDF18 printed17, technical specifications; exact GL20-0004ETP-2A-INT guide material01441059. · Only the guide-qualified material/version; retain historical material01440787 separately. Load types have different power/frequency/inrush limits. Disabling a diagnostic may remove a required application fault-detection function; engineering review required.
Control & interfaces
Equipment inductive output load (W)
View structured source values
Per channel
28.8
Per module
57.6
W; distinct from resistive rating
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Literal equipment guide technical table · A00 PDF18 printed17, technical specifications; exact GL20-0004ETP-2A-INT guide material01441059. · Only the guide-qualified material/version; retain historical material01440787 separately. Load types have different power/frequency/inrush limits. Disabling a diagnostic may remove a required application fault-detection function; engineering review required.
Equipment lamp output load (W)
10 W per channel
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Literal equipment guide technical table · A00 PDF18 printed17, technical specifications; exact GL20-0004ETP-2A-INT guide material01441059. · Only the guide-qualified material/version; retain historical material01440787 separately. Load types have different power/frequency/inrush limits. Disabling a diagnostic may remove a required application fault-detection function; engineering review required.
Equipment output isolation source text
Supported No voltage, reinforced-insulation class or group-to-group rating stated in this table
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Literal equipment guide technical table · A00 PDF18 printed17, technical specifications; exact GL20-0004ETP-2A-INT guide material01441059. · Only the guide-qualified material/version; retain historical material01440787 separately. Load types have different power/frequency/inrush limits. Disabling a diagnostic may remove a required application fault-detection function; engineering review required.
Equipment output load resistance ohm
12 · 4000 ohm
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Equipment output source type
PNP
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Hardware output response (µs)
100 µs
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Resistive output load per module (A)
8 A
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp8; exact commercial code table. Detailed output table visually reviewed. Resistive-load rating only; inductive/lamp loads and ambient derating require the manual. No wiring or load approval.
Resistive output load per point (A)
2 A
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp8; exact commercial code table. Detailed output table visually reviewed. Resistive-load rating only; inductive/lamp loads and ambient derating require the manual. No wiring or load approval.
Additional product data
A01 coupler scope
Manufacturer INT brochure lists the named signal module with these coupler order codes. Actual material/firmware/device-description/slot/current compatibility must still be verified; no domestic equipment guide is transferred by similar naming.
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Exact INT brochure model-name association; firmware applicability remains conditional · PDF9 exact INT module table and supported-coupler row; Exact INT brochure model-name association; firmware applicability remains conditional. Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability. · Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability.
Equipment guide identity scope
Exact INT model and material row in this equipment guide. Historical brochure material identities remain separately recorded; new guide ratings are conditional on procuring this qualified material/version.
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
Equipment guide version
A00
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
Equipment high resistance open circuit diagnostic note
Above4000ohm the module may incorrectly report open-circuit faults; the manufacturer recommends disabling open-circuit fault diagnosis. This diagnostic condition does not establish a physical inability to drive all such loads.
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Literal equipment guide technical table · A00 PDF18 printed17, technical specifications; exact GL20-0004ETP-2A-INT guide material01441059. · Only the guide-qualified material/version; retain historical material01440787 separately. Load types have different power/frequency/inrush limits. Disabling a diagnostic may remove a required application fault-detection function; engineering review required.
Equipment lamp inrush profile
View structured source values
Maximum (A)
10
Maximum duration (µs)
300
source lamp-load condition, not a universal pulse-current rating
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Literal equipment guide technical table · A00 PDF18 printed17, technical specifications; exact GL20-0004ETP-2A-INT guide material01441059. · Only the guide-qualified material/version; retain historical material01440787 separately. Load types have different power/frequency/inrush limits. Disabling a diagnostic may remove a required application fault-detection function; engineering review required.
Equipment off state leakage ua
50 µA
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact current-guide material01441059 only · PDF18 printed17, exact output specification and derating rows; Exact current-guide material01441059 only. Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials. · Resistive load only in the capacity screen. Inductive0.5Hz and lamp10Hz differ from resistive100Hz. Open-circuit detection may need disabling above4000ohm; that does not establish a load outside the reviewed range. No leakage correction is asserted for unverified older materials.
Operating temperature c
-20 · 55 °C
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp8; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.

Documents & Sources

Check that the document covers your exact model and revision.

Technical reference · GL20

Inovance GL20 international I/O brochure V0.3 ↗

Revision
Not recorded
Linked parts
30
View linked parts

Supplier-prepared technical reference. RS acceptance remains pending; confirm the exact material revision when quoting.

Exact part reference: page=8

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Technical reference

Datasheet / brochure · GL20

Inovance GL20-INT I/O system brochure A01 ↗

Revision
A01
Linked parts
35
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=9

Original manufacturer reference: Source 1 ↗ Source 2 ↗ Source 3 ↗ Source 4 ↗ Source 5 ↗ Source 6 ↗ Source 7 ↗ Source 8 ↗ Source 9 ↗ Source 10 ↗ Source 11 ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Datasheet / brochure

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team