Technical Specifications

Check the listed ratings and operating conditions for your application before ordering.

FeatureDocumented value
Electrical & performance
A01 output current scope
A01 exact INT table; standard PNP8/16point totals1A/2A are lower than the earlier4A brochure. NPN8/16point totals2A/4A remain unchanged. Use the minimum retained current capacity; confirm installed/offered material revision and load/environment conditions. No previous higher rating is silently overwritten.
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Current A01 international brochure load and coupler table · PDF8 exact GL20-0008ETN-INT table; Current A01 international brochure load and coupler table. This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks. · This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks.
A01 output voltage (V DC)
21.6 · 26.4 V DC
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Current A01 international brochure load and coupler table · PDF8 exact GL20-0008ETN-INT table; Current A01 international brochure load and coupler table. This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks. · This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks.
Control & interfaces
Digital outputs
8 count
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Output polarity
NPN
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Installation & mechanics
Ingress protection
IP20
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp9; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
Additional product data
A01 supported I/O couplers
GL20-RTU-ECT32-INT · GL20-RTU-EIP-INT · GL20-RTU-PN-INT
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Current A01 international brochure load and coupler table · PDF8 exact GL20-0008ETN-INT table; Current A01 international brochure load and coupler table. This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks. · This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks.
Manufacturer material code
01440775
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
More specifications & source notes 6 additional fields
FeatureDocumented value
Control & interfaces
A01 resistive output load per module (A)
2 A
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Current A01 international brochure load and coupler table · PDF8 exact GL20-0008ETN-INT table; Current A01 international brochure load and coupler table. This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks. · This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks.
A01 resistive output load per point (A)
0.5 A
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Current A01 international brochure load and coupler table · PDF8 exact GL20-0008ETN-INT table; Current A01 international brochure load and coupler table. This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks. · This is a version-qualified lower capacity bound,not evidence that every old material is identical. Resistance,inductive/lamp,inrush,leakage,timing,voltage drop and all thermal/installation limits remain separate application checks.
Hardware output response (µs)
100 µs
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Resistive output load per module (A)
4 A
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp9; exact commercial code table. Detailed output table visually reviewed. Resistive-load rating only; inductive/lamp loads and ambient derating require the manual. No wiring or load approval.
Resistive output load per point (A)
0.5 A
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp9; exact commercial code table. Detailed output table visually reviewed. Resistive-load rating only; inductive/lamp loads and ambient derating require the manual. No wiring or load approval.
Additional product data
Operating temperature c
-20 · 55 °C
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp9; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.

Documents & Sources

Check that the document covers your exact model and revision.

Technical reference · GL20

Inovance GL20 international I/O brochure V0.3 ↗

Revision
Not recorded
Linked parts
30
View linked parts

Supplier-prepared technical reference. RS acceptance remains pending; confirm the exact material revision when quoting.

Exact part reference: page=9

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Technical reference

Datasheet / brochure · GL20

Inovance GL20-INT I/O system brochure A01 ↗

Revision
A01
Linked parts
35
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=8

Original manufacturer reference: Source 1 ↗ Source 2 ↗ Source 3 ↗ Source 4 ↗ Source 5 ↗ Source 6 ↗ Source 7 ↗ Source 8 ↗ Source 9 ↗ Source 10 ↗ Source 11 ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Datasheet / brochure

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team