FeatureDocumented value
Electrical & performance
Bus current limit at 45 to 55 c (A)
1.6 A
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed model table, PDF p6, visually reviewed. No certification or application approval inferred.
Bus output nominal current (A)
2 A
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed coupler table visually reviewed. 2 A nominal bus output; EtherNet/IP derates to maximum 1.6 A at 45–55°C. Power budget and installed firmware still require review.
Terminal supply (V DC)
20.4 · 28.8 V DC
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed coupler table visually reviewed. 2 A nominal bus output; EtherNet/IP derates to maximum 1.6 A at 45–55°C. Power budget and installed firmware still require review.
Control & interfaces
Bus output (V DC)
4.75 · 5.25 V DC
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed coupler table visually reviewed. 2 A nominal bus output; EtherNet/IP derates to maximum 1.6 A at 45–55°C. Power budget and installed firmware still require review.
Installation & mechanics
Ingress protection
IP20
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
Additional product data
Bus protocol
EtherNet/IP
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Expansion modules max
16 count
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed model table, PDF p6, visually reviewed. No certification or application approval inferred.
Manufacturer material code
01440924
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
More specifications & source notes 5 additional fields
FeatureDocumented value
Additional product data
Depth (mm)
83 mm
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed coupler table visually reviewed. 2 A nominal bus output; EtherNet/IP derates to maximum 1.6 A at 45–55°C. Power budget and installed firmware still require review.
Height (mm)
100 mm
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed coupler table visually reviewed. 2 A nominal bus output; EtherNet/IP derates to maximum 1.6 A at 45–55°C. Power budget and installed firmware still require review.
Operating temperature c
-20 · 55 °C
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
Selection chart expansion modules max
16 count
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Width (mm)
24 mm
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp6; exact commercial code table. Detailed coupler table visually reviewed. 2 A nominal bus output; EtherNet/IP derates to maximum 1.6 A at 45–55°C. Power budget and installed firmware still require review.

Documents & Sources

Check that the document covers your exact model and revision.

Technical reference · GL20

Inovance GL20 international I/O brochure V0.3 ↗

Revision
Not recorded
Linked parts
30
View linked parts

Supplier-prepared technical reference. RS acceptance remains pending; confirm the exact material revision when quoting.

Exact part reference: page=6

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Technical reference

Datasheet / brochure · GL20

Inovance GL20-INT I/O system brochure A01 ↗

Revision
A01
Linked parts
35
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=6

Original manufacturer reference: Source 1 ↗ Source 2 ↗ Source 3 ↗ Source 4 ↗ Source 5 ↗ Source 6 ↗ Source 7 ↗ Source 8 ↗ Source 9 ↗ Source 10 ↗ Source 11 ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Datasheet / brochure

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team