| Additional product data |
|---|
| A01 coupler scope | Manufacturer INT brochure lists the named signal module with these coupler order codes. Actual material/firmware/device-description/slot/current compatibility must still be verified; no domestic equipment guide is transferred by similar naming.Source & conditions- Revision
- 19120523-CY A01,28August2025
- Applies to
- Exact INT brochure model-name association; firmware applicability remains conditional · PDF13 exact INT module table and supported-coupler row; Exact INT brochure model-name association; firmware applicability remains conditional. Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability. · Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability.
|
|---|
| Equipment guide identity scope | Exact INT model and material row in this equipment guide. Historical brochure material identities remain separately recorded; new guide ratings are conditional on procuring this qualified material/version.Source & conditions- Revision
- Equipment guide A01; exact material/version scope retained
- Applies to
- Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
|
|---|
| Equipment guide version | A01Source & conditions- Revision
- Equipment guide A01; exact material/version scope retained
- Applies to
- Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
|
|---|
| Equipment pt100 accuracy segments | View structured source valuesRecorded point 1- Range c
- -200 · 300
- Upper exclusive
- Yes
- Error c
- 1
Recorded point 2- Range c
- 300 · 700
- Error c
- 2
Recorded point 3- Range c
- 700 · 850
- Lower exclusive
- Yes
- Error c
- 2.5
Source & conditions- Revision
- Equipment guide A01; exact material/version scope retained
- Applies to
- exact-model table · PDF18–19 Pt100 type/range/accuracy and wiring rows; exact-model table. Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity. · Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity.
|
|---|
| Equipment pt100 coefficient scope | Guide namesPt100 but does not state its temperature coefficient. Confirm the target calibration curve and exact source alpha before quotation; no equivalence betweenPt100 alpha0.00385 and0.003916 is inferred.Source & conditions- Revision
- Equipment guide A01; exact material/version scope retained
- Applies to
- exact-model table · PDF18–19 Pt100 type/range/accuracy and wiring rows; exact-model table. Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity. · Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity.
|
|---|
| Equipment pt100 range c | -200 · 850 deg CSource & conditions- Revision
- Equipment guide A01; exact material/version scope retained
- Applies to
- exact-model table · PDF18–19 Pt100 type/range/accuracy and wiring rows; exact-model table. Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity. · Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity.
|
|---|
| Equipment rtd wiring methods | 2-wire · 3-wireSource & conditions- Revision
- Equipment guide A01; exact material/version scope retained
- Applies to
- exact-model table · PDF18–19 Pt100 type/range/accuracy and wiring rows; exact-model table. Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity. · Only a namedPt100 function screen is available until coefficient/range/accuracy and actual sensor/wiring are confirmed. SourcePt200,Cu10,Ni types and raw resistance modes are not assigned to GL20 by name similarity.
|
|---|
| Operating temperature c | -20 · 55 °CSource & conditions- Revision
- GL20 brochure V0.3
- Applies to
- exact commercial code table · PDFp14; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
|
|---|
| Sampling period (ms) | 250 · 500 · 1000 msSource & conditions- Revision
- GL20 brochure V0.3
- Applies to
- exact commercial code table · PDFp14; exact commercial code table. PDF p14: selectable sampling periods for FOUR channels, configurable in software. Sensor wiring and accuracy need the manual.
|
|---|
| Temperature accuracy scope | Brochure quotes ADC sampling accuracy only; specific temperature measurement accuracy requires the user manual.Source & conditions- Revision
- GL20 brochure V0.3
- Applies to
- exact-model table · PDFp14 (printed26–27), exact GL20-4PT-INT table; exact-model table. 2/3wire only in this source; no4wire compatibility inferred. ADC0.1% at25C/0.3% overtemperature is not claimed as complete sensor/lead-system accuracy. · 2/3wire only in this source; no4wire compatibility inferred. ADC0.1% at25C/0.3% overtemperature is not claimed as complete sensor/lead-system accuracy.
|
|---|
| Temperature filter time default s | 5 sSource & conditions- Revision
- GL20 brochure V0.3
- Applies to
- exact-model table · PDFp14 (printed26–27), exact GL20-4PT-INT table; exact-model table. 2/3wire only in this source; no4wire compatibility inferred. ADC0.1% at25C/0.3% overtemperature is not claimed as complete sensor/lead-system accuracy. · 2/3wire only in this source; no4wire compatibility inferred. ADC0.1% at25C/0.3% overtemperature is not claimed as complete sensor/lead-system accuracy.
|
|---|
| Temperature filter time range s | 0 · 100 sSource & conditions- Revision
- GL20 brochure V0.3
- Applies to
- exact-model table · PDFp14 (printed26–27), exact GL20-4PT-INT table; exact-model table. 2/3wire only in this source; no4wire compatibility inferred. ADC0.1% at25C/0.3% overtemperature is not claimed as complete sensor/lead-system accuracy. · 2/3wire only in this source; no4wire compatibility inferred. ADC0.1% at25C/0.3% overtemperature is not claimed as complete sensor/lead-system accuracy.
|
|---|