Inovance GL20-4DA-INT

Manufacturer illustration. Confirm the exact physical variant.

Inovance / Remote I/O

GL20-4DA-INT

Remote I/O

Brand
Inovance
Family
GL20
Product type
Remote I/O

Price, availability and application suitability are confirmed by our team.

Technical Specifications

Check the listed ratings and operating conditions for your application before ordering.

FeatureDocumented value
Electrical & performance
Analog current output load range ohm
0 · 600 ohm
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact-model table · PDFp12 (printed22–23), exact GL20-4DA-INT table; exact-model table. Published load point andpartial-isolation scope only. No source/target grounding,complete loop accuracy,capacitance,settling ortemperature compatibility approval. · Published load point andpartial-isolation scope only. No source/target grounding,complete loop accuracy,capacitance,settling ortemperature compatibility approval.
Analog current ranges
0–20 mA · 4–20 mA
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp12; exact commercial code table. Detailed model table, PDF p12, visually reviewed. No certification or application approval inferred.
Analog voltage output published load ohm
1000 ohm; published load point, not an inferred extended range
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact-model table · PDFp12 (printed22–23), exact GL20-4DA-INT table; exact-model table. Published load point andpartial-isolation scope only. No source/target grounding,complete loop accuracy,capacitance,settling ortemperature compatibility approval. · Published load point andpartial-isolation scope only. No source/target grounding,complete loop accuracy,capacitance,settling ortemperature compatibility approval.
Analog voltage ranges
±10 V · 0–10 V · ±5 V · 0–5 V · 1–5 V
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp12; exact commercial code table. Reviewed detailed analog column; selectable voltage ranges, not simultaneous independent channels.
Equipment current output accuracy percent fs 25c
0.1 %FS at 25 C
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact module / explicitly scoped model-column specification · GL20-4DA A00 equipment guide PDFp19 printed18 exact material 01441089 output table · Qualification applies only to the guide-listed material/version. Older brochure material and ratings remain separate. No operating-range or ambient extrapolation.
Equipment current output accuracy percent fs full temperature
0.5 %FS; separate installation/derating applies
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact module / explicitly scoped model-column specification · GL20-4DA A00 equipment guide PDFp19 printed18 exact material 01441089 output table · Qualification applies only to the guide-listed material/version. Older brochure material and ratings remain separate. No operating-range or ambient extrapolation.
Equipment current output ambient bound c
40 deg C; analyst conservative bound inside published graph
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact guide material01441089; conservative installation bound separately labelled · PDF19 output specs and PDF22 printed21 load/temperature/channel derating graphs; Exact guide material01441089; conservative installation bound separately labelled. Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation. · Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation.
Equipment current output installation scope
Conservative four-channel current-output starting point: horizontal mounting at ambient<=40C,loop0–600ohm. This interior operating bound was checked against the guide graph onPDF22; it is not the full published mounting/temperature envelope. Non-horizontal operation and higher ambient require separate graph/channel-count review.
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact guide material01441089; conservative installation bound separately labelled · PDF19 output specs and PDF22 printed21 load/temperature/channel derating graphs; Exact guide material01441089; conservative installation bound separately labelled. Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation. · Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation.
Equipment current output load range ohm
0 · 600 ohm
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact guide material01441089; conservative installation bound separately labelled · PDF19 output specs and PDF22 printed21 load/temperature/channel derating graphs; Exact guide material01441089; conservative installation bound separately labelled. Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation. · Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation.
Equipment current output modes (mA)
0-20 · 4-20 mA; select4-20 only for this configuration
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact module / explicitly scoped model-column specification · GL20-4DA A00 equipment guide PDFp19 printed18 exact material 01441089 output table · Qualification applies only to the guide-listed material/version. Older brochure material and ratings remain separate. No operating-range or ambient extrapolation.
Equipment current output mounting
Horizontal
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact guide material01441089; conservative installation bound separately labelled · PDF19 output specs and PDF22 printed21 load/temperature/channel derating graphs; Exact guide material01441089; conservative installation bound separately labelled. Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation. · Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation.
Equipment current output supply (V DC)
20.4 · 28.8 V DC; terminal input allowable range
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact module / explicitly scoped model-column specification · GL20-4DA A00 equipment guide PDFp19 printed18 exact material 01441089 output table · Qualification applies only to the guide-listed material/version. Older brochure material and ratings remain separate. No operating-range or ambient extrapolation.
Control & interfaces
Analog resolution bits
16 bit
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Analogue outputs
4 count
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
Installation & mechanics
Ingress protection
IP20
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp12; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
Additional product data
A01 supported coupler codes
GL20-RTU-ECT32-INT · GL20-RTU-EIP-INT · GL20-RTU-PN-INT
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Exact INT brochure model-name association; firmware applicability remains conditional · PDF12 exact INT module table and supported-coupler row; Exact INT brochure model-name association; firmware applicability remains conditional. Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability. · Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability.
Analog channel isolation
No isolation between interface channels; interface,power and backplane are partially isolated
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact-model table · PDFp12 (printed22–23), exact GL20-4DA-INT table; exact-model table. Published load point andpartial-isolation scope only. No source/target grounding,complete loop accuracy,capacitance,settling ortemperature compatibility approval. · Published load point andpartial-isolation scope only. No source/target grounding,complete loop accuracy,capacitance,settling ortemperature compatibility approval.
Equipment guide required material code
01441089
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
Manufacturer material code
01440741
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.
More specifications & source notes 7 additional fields
FeatureDocumented value
Additional product data
A01 coupler scope
Manufacturer INT brochure lists the named signal module with these coupler order codes. Actual material/firmware/device-description/slot/current compatibility must still be verified; no domestic equipment guide is transferred by similar naming.
Source & conditions
Revision
19120523-CY A01,28August2025
Applies to
Exact INT brochure model-name association; firmware applicability remains conditional · PDF12 exact INT module table and supported-coupler row; Exact INT brochure model-name association; firmware applicability remains conditional. Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability. · Not an interoperability or safety approval. Preserve source-version timing differences; manufacturer catalogue presence is not Australian availability.
Equipment analogue channel isolation
No
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Exact guide material01441089; conservative installation bound separately labelled · PDF19 output specs and PDF22 printed21 load/temperature/channel derating graphs; Exact guide material01441089; conservative installation bound separately labelled. Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation. · Voltage mode only has a published1kohm load point, not a declared universal impedance range. Four-channel current-mode use needs both loop and mounting/ambient checks; vertical PLC mounting has a six-module constraint. No voltage-load range or thermal extrapolation.
Equipment guide identity scope
Exact INT model and material row in this equipment guide. Historical brochure material identities remain separately recorded; new guide ratings are conditional on procuring this qualified material/version.
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
Equipment guide version
A00
Source & conditions
Revision
Equipment guide A00; exact material/version scope retained
Applies to
Version-qualified exact manufacturer order code · PDF14 exact INT model/material row; Version-qualified exact manufacturer order code. No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation. · No supplier stock,price,certification or automatic substitution approval. Confirm material and applicable guide revision before quotation.
Operating temperature c
-20 · 55 °C
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp12; exact commercial code table. Detailed GL20 model table visually reviewed; operating range only. Individual load/power derating and enclosure integration remain separate constraints.
Per channel conversion time (µs)
60 µs
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp12; exact commercial code table. Detailed table visually reviewed: conversion time is explicitly PER CHANNEL for 4AD/4DA (60 µs/channel). The p18 selection chart lists 250 µs without a timing basis; keep both fields separate.
Selection chart conversion time (µs)
250 µs
Source & conditions
Revision
GL20 brochure V0.3
Applies to
exact commercial code table · PDFp18; exact commercial code table. Selection chart, PDF p18 (printed pp34–35), visually reviewed. No certification or application approval inferred.

Documents & Sources

Check that the document covers your exact model and revision.

Technical reference · GL20

Inovance GL20 international I/O brochure V0.3 ↗

Revision
Not recorded
Linked parts
30
View linked parts

Supplier-prepared technical reference. RS acceptance remains pending; confirm the exact material revision when quoting.

Exact part reference: page=12

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Technical reference

Datasheet / brochure · GL20

Inovance GL20-INT I/O system brochure A01 ↗

Revision
A01
Linked parts
35
View linked parts

Manufacturer document. Check the cited page, revision and exact ordering code.

Exact part reference: page=12

Original manufacturer reference: Source 1 ↗ Source 2 ↗ Source 3 ↗ Source 4 ↗ Source 5 ↗ Source 6 ↗ Source 7 ↗ Source 8 ↗ Source 9 ↗ Source 10 ↗ Source 11 ↗

Source association does not confirm suitability for every variant. Check model coverage inside the document.
Datasheet / brochure

Need Help Selecting the Right Part?

Send the part number and your application requirements. We can check the configuration with you.

Talk to our team